1.
J Immunol Methods ; 498: 113135, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34478717

RESUMO

In recent years, there has been an expansion in the use of flow cytometry (FC) immunophenotyping in the diagnosis and monitoring of childhood solid neoplasms. Neuroblastoma (NB), in turn, is the most common extracranial solid tumor in childhood. In the present study, we sought to compare FC and anatomopathological examination (PA) / immunohistochemistry (IHC) of children diagnosed or suspected with NB. The median age was 59 months (minimum 0; maximum 325 months), of these 12 were male (57.1%, 12/21). Forty-eight samples (27 bone marrow (BM), 10 peripheral blood (PB), 8 primary tumors (PT) and 2 liver nodules (HN) and 1 rib fragment (RF)) from 21 patients were evaluated. Twenty-nine samples were from patients with clinical suspicion while 19 samples were from patients with previously confirmed diagnosis. Thirteen samples (7 BM, 5 PT and 1 HN) presented NB when analyzed in FC while 8 (3 BM and 5 PT) samples were positive for NB in the PA/IHC. They were concordant in 88.9% of the cases. No NB cells were identified in any PB. Considering the PA as the gold standard, the FC obtained a sensitivity of 100%, a specificity of 86%, a positive predictive value of 67% and a negative predictive value of 100%. This study demonstrates that FC can be used as a methodology for diagnosis and assessment of NB involvement. In addition, FC has the advantage of allowing a quick diagnosis and accurate classification of the disease, and can also assist in monitoring the treatment.


Assuntos
Biomarcadores Tumorais/análise , Citometria de Fluxo , Imuno-Histoquímica , Neuroblastoma/diagnóstico , Biomarcadores Tumorais/genética , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Neuroblastoma/química , Neuroblastoma/genética , Neuroblastoma/imunologia , Ploidias , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Fluxo de Trabalho
2.
J. Bras. Patol. Med. Lab. (Online) ; 57: e3082021, 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1350875

RESUMO

RESUMEN Los tumores sólidos infantiles representan aproximadamente el 30% de todos los cánceres pediátricos. En los últimos años se ha incrementado el uso de la citometría de flujo (CF) en el diagnóstico y seguimiento de estas patologías, ya que es un método que permite obtener resultados rápidos y precisos, posibilitando un manejo más precoz. Realizamos esta revisión sistemática para la búsqueda bibliográfica de los siguientes términos en las plataformas de datos Lilacs, PubMed y Scielo: neoplasma, oncología, pediatría, inmunofenotipificación y citometría de flujo. Así, describimos los principales hallazgos hasta la fecha sobre el uso de CF en el diagnóstico diferencial de los cinco principales tumores de células pequeñas, redondas y azules de la infancia: neuroblastoma, sarcoma de Ewing, tumor neuroectodérmico primitivo, tumor de Wilms y rabdomiosarcoma. Además, describimos las principales ventajas y desventajas del método y paneles que se proponen en el diagnóstico diferencial de estas patologías a través de la literatura internacional. A través de esta revisión, observamos que el uso de CF en el diagnóstico de tumores sólidos puede ser útil para la identificación rápida y precisa de la efermedade, así como para el inicio más temprano del tratamiento.

3.
J Bras Nefrol ; 39(2): 181-185, 2017.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29069242

RESUMO

INTRODUCTION: Immunosuppression of T lymphocytes is required for preventing acute rejection after transplantation and for the treatment of chronic autoimmune and inflammatory diseases. The laboratory monitoring for this therapy is the measurement of T cells by immunophenotyping, aiming the target value of less than 20 cells per µL. OBJECTIVE: To establish a cut-off point for the total number of lymphocytes in the automated blood cell count that reflects less than twenty T cells µL by immunophenotyping. METHODS: We studied and evaluated 242 kidney transplant patients that had results of automated blood cell count and quantification of T cells by immunophenotyping technique. The patients were divided into two groups, depending on the T lymphocyte immunophenotyping rates established by lower and higher than 20 cells per µL. After, we evaluated the cut-off point for lymphocytes in the blood cell count with a specificity of 100% to exclude patients with high levels of T lymphocytes. RESULTS: We found that the cut-off point of 70 lymphocytes per µL obtained by automated blood cell count showed 100% of specificity to exclude patients with T-cell counts higher than 20 cells per µL by immunophenotyping. CONCLUSION: The results found in this study may be helpful to monitor the immunosuppressive therapy in kidney transplant patients in places where a flow cytometer is not available, or when this equipment is not present in the full routine.


Assuntos
Soro Antilinfocitário/uso terapêutico , Complexo CD3 , Terapia de Imunossupressão , Imunossupressores/uso terapêutico , Transplante de Rim , Linfócitos T/imunologia , Monitoramento de Medicamentos , Feminino , Humanos , Imunofenotipagem/métodos , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
J. bras. nefrol ; 39(2): 181-185, Apr.-June 2017. graf
Artigo em Inglês | LILACS | ID: biblio-893754

RESUMO

Abstract Introduction: Immunosuppression of T lymphocytes is required for preventing acute rejection after transplantation and for the treatment of chronic autoimmune and inflammatory diseases. The laboratory monitoring for this therapy is the measurement of T cells by immunophenotyping, aiming the target value of less than 20 cells per µL. Objective: To establish a cut-off point for the total number of lymphocytes in the automated blood cell count that reflects less than twenty T cells µL by immunophenotyping. Methods: We studied and evaluated 242 kidney transplant patients that had results of automated blood cell count and quantification of T cells by immunophenotyping technique. The patients were divided into two groups, depending on the T lymphocyte immunophenotyping rates established by lower and higher than 20 cells per µL. After, we evaluated the cut-off point for lymphocytes in the blood cell count with a specificity of 100% to exclude patients with high levels of T lymphocytes. Results: We found that the cut-off point of 70 lymphocytes per µL obtained by automated blood cell count showed 100% of specificity to exclude patients with T-cell counts higher than 20 cells per µL by immunophenotyping. Conclusion: The results found in this study may be helpful to monitor the immunosuppressive therapy in kidney transplant patients in places where a flow cytometer is not available, or when this equipment is not present in the full routine.


Resumo Introdução: A imunossupressão de linfócitos T é necessária para a prevenção da rejeição aguda em transplantes e no tratamento de doenças autoimunes e inflamatórias crônicas. O seu monitoramento laboratorial consiste na quantificação dos linfócitos T realizada pela técnica de imunofenotipagem, na qual o valor preconizado é manter inferior a 20 células/µL. Objetivo: Estabelecer um ponto de corte para o número de linfócitos totais no hemograma automatizado que reflita uma contagem de linfócitos T inferior a 20 células/µL por imunofenotipagem. Métodos: Foram avaliados 242 pacientes transplantados renais que continham resultados do hemograma automatizado e quantificação de linfócitos T por imunofenotipagem. Os pacientes foram divididos em dois grupos, conforme os valores de linfócitos T estabelecidos pela imunofenotipagem: inferiores e superiores a 20 células/µL. A partir disto, foi avaliado o ponto de corte de linfócitos no hemograma com especificidade de 100% para excluir os pacientes com valores elevados de linfócitos T. Resultados: Este estudo evidenciou que o ponto de corte de 70 linfócitos/µL obtidos pelo hemograma automatizado apresentou especificidade de 100% para excluir os pacientes com contagens de linfócitos T superiores a 20 células/µL na imunofenotipagem. Conclusão: Esta pesquisa poderá auxiliar no monitoramento da terapia imunossupressora em pacientes transplantados renais em locais que não possuem um citômetro de fluxo disponível, ou ainda quando este equipamento não se faz presente na rotina integral.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Linfócitos T/imunologia , Terapia de Imunossupressão , Transplante de Rim , Complexo CD3 , Imunossupressores/uso terapêutico , Soro Antilinfocitário/uso terapêutico , Estudos Retrospectivos , Imunofenotipagem/métodos , Monitoramento de Medicamentos , Contagem de Linfócitos